Air Conditioning System Design for Data Center (CIBSE Approved CPD Course)
14/F, On Lok Yuen Building, 25-27A Des Voeux Rd Central, Central, Hong Kong
23 March 2017 - 24 March 2017
Air Conditioning System Design for Data Center (CIBSE Approved CPD Course)
23 March 2017 - 24 March 2017
Organized by Strategic Media Asia (SMA)
Workshop or Training Course Science & Technology
HK$4,230.00



Air Conditioning System Design for Data Center (2-day)

(23 - 24 March 2017, approved CPD course by CIBSE UK)


Further to the topics in Data Center Facilities Design & Infrastructure Engineering, this is an advanced section for engineers involved in designing or handling HVAC (Heating, Ventilation and Air Conditioning) equipment for mission-critical buildings and data center projects.

 

      

      


You'll be able to make informed decisions about the best choices of cooling systems for critical purposes and how system can best meet your project goal and SLA (Service Level Agreement).

 

Date: 23 - 24 March 2017 (Thursday - Friday)
Time: 10:00 - 17:30
Venue: 14/F, On Lok Yuen Building, 25 - 27A Des Voeux Road Central, Hong Kong (Exit B, Central Station)

> Datacom Equipment Power Trends and Cooling Applications

-- Load trends and their application
-- Air cooling of computer equipment
-- Liquid cooling of computer equipment


> Design Consideration

-- Design criteria
-- HVAC load
-- Computer room cooling
-- Air distribution
-- Liquid cooling
-- Availability and redundancy
-- Controls
-- Integration with other MEP (Mechanical, Electrical and Plumbing) system
-- Computer Fluid Dynamics (CFD)


> Testing and Commissioning

-- Air cleanliness test
-- Heat load test
-- Factory acceptance test
-- Site acceptance test
-- Integrated performance test (IST)


> Energy Efficiency


-- Power usage effectiveness
-- Chilled water plant optimization
-- Water side and air side equipment
-- Part load operation
-- Controls and energy management
-- LEED certified data center
-- Building energy code


> Sustainable Design


-- Combined heat power plant (CHP)
-- Solar cooling
-- Geothermal cooling
-- Evaporative cooling
-- Air side economizers
-- Desiccant unit


It highlights design principles such as psychrometric chart, cooling load calculation / estimation, etc. and the design considerations such as air distribution, availability / redundancy, common mistakes, Computer Fluid Dynamic (CFD) model, integration with MEPs (Mechanical, Electrical and Plumbing system), etc.


For details, please refer to http://www.stmedia-asia.com/newsletter_6.html.

 

About the Organizer

Strategic Media Asia Limited (SMA) is one of the approved CPD course providers of the Chartered Institution of Building Services Engineers (CIBSE) UK.

Our mission is to provide an interactive environment and opportunities for members of ICT industry and facilities' engineers to exchange professional views and experience. For details, please visit www.stmedia-asia.com/about.html.


Adverse Weather Arrangement - Events in the morning, afternoon or evening will be cancelled if typhoon signal No. 8 or above or black rainstorm warning is still hoisted after (or is announced by the Hong Kong Observatory to be hoisted at / after) 6:00 a.m., 11:00 a.m. and 4:00 p.m. respectively. Delegates will be notified when the class will be made up as soon as possible.



Strategic Media Asia Limited
Connecting IT, Facilities and Design

T (852) 2117 3893 | F (852) 2184 9978

Room 403, 4th Floor, Dominion Centre, 43 - 59 Queen's Road East, Hong Kong
http://www.stmedia-asia.com | http://green-data.blogspot.com

 

 

14/F, On Lok Yuen Building, 25-27A Des Voeux Rd Central, Central, Hong Kong
Thursday 23 March 2017 10:00am - Friday 24 March 2017 5:30pm  GMT+08:00